Configuration
108
Name/function
Explanation
Siren time Int. [min]
Time for the duration of the internal siren(s) in minutes after a burglar alarm.
The siren time can be set to a value between 0 and 20 min.
If sounders are assigned to multiple partitions, the alarm panel uses the longest si-
ren time set for the partitions in question.
The time for which the sounders are active can also be extended to the longest si-
ren delay for that partition.
Note
Internal sirens always sound after a fire or hold up alarm until the alarm is confirmed
by a user for safety reasons. For safety reasons there is no time limit for a fire alarm
or hold up alarm.
Special response when an entry delay is used
Requirement
The internal sounders (alarm panel, wireless indoor siren, wireless info module)
are muted again after the internal siren time has expired.
The alarm panel has automatically rearmed (see also "Installer Mode
System -
> Security
Auto Rearm").
Response
If you now enter the entrance area ("Final Door" and "Entry/Exit Follow" detectors
are opened), the internal sounders (alarm panel, wireless indoor siren, wireless
info module) emit an
alarm tone
.
The
normal entry tone
is
not signalled
in this case.
Note
When the entry delay is used, you would usually expect to hear the normal entry
tone. This entry tone should be heard as long as the entry delay is running. If you
hear an alarm tone after opening the entrance door, you know immediately that the
alarm panel has detected an intrusion during your absence.
The delay time runs anyway. Disarm the alarm panel within the delay time.
Do so
only if you feel it is safe, however. An intruder could still be inside the prop-
erty!
If you do not disarm the system, an additional burglar alarm is triggered once
the delay time has expired.
Notify others who have access to your property of this response of the alarm panel.
Endless
On
Internal sirens signal the alarm tone until an alarm is acknowledged by a user.
Off
The siren time for the duration of the internal siren(s) is used.
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......