Configuration
77
Type
Explanation
Can be assigned
to partitions
HUA Confirm Timer
This output is activated while the timer for confirmation of
a hold up alarm is running and is deactivated as soon as
the timer has expired.
No
Duress Code
A duress code has been used. The alarm panel activates
the output as soon as a user enters a duress code and
deactivates the output again when the user resets the
system.
Yes
Confirmed Alarm
This output is activated when an alarm is interrupted by
the user in the selected partition during the possible time
period. The output is deactivated again when the alarm is
confirmed.
Yes
Fire
This output is activated when a fire alarm is triggered.
yes
Technical Alarm
This output is activated when a zone with the attribute
"Technical Alarm" triggers an alarm. It is only deactivated
again when the zone triggering the alarm is reset (cause
for the technical alarm has been corrected) AND the user
confirms the technical alarm on the alarm panel with a
valid code.
Yes
24 hours)
This output is activated when a zone with the attribute "24
Hour Alarm" triggers an alarm.
Yes
Zone Alarm
This output is activated when the selected zone reports
an alarm and is deactivated again when the alarm is re-
set.
No
External Siren
This output is activated when there is a local alarm in the
selected partition for the set siren time of the external si-
ren.
The output does not activate for a technical alarm or hold
up alarm.
Yes
Internal Siren
This output is activated when there is a local alarm in the
selected partition for the set siren time of the internal si-
ren.
The output does not activate for a technical alarm or hold
up alarm.
Yes
External Strobe
This output is activated when there is a local alarm in the
selected partition and remains activated until the wireless
alarm panel is disarmed.
The output is also activated for 10 seconds after the parti-
tion has been successfully armed if the
EXTERNAL
strobe signal for confirmation has been activated.
Yes
Internal Strobe
This output is activated when there is a local alarm in the
selected partition and remains activated until the wireless
alarm panel is disarmed.
The output is also activated for 10 seconds after the parti-
tion has been successfully armed if the
INTERNAL
strobe
signal for confirmation has been activated.
Yes
Alarm Abort
The output is activated when an alarm is interrupted by
the user in the selected partition during the possible time
period. The output is deactivated as soon as the alarm is
confirmed.
Yes
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......