The JA-152P / JA-152P (G) Wireless PIR motion detector 

The JA-152P / JA-152P (G) Wireless PIR motion detector 

1 / 2 

MMO57101 

The JA-152P (JA-152P (G)) is a wireless device of the 

JABLOTRON 

100

  system. It is used to detect movement of persons in interiors  

of buildings. Its guaranteed detection coverage is 90° horizontally and 

the detection range is 12 m. The detector with a 

white lens

 (JA-152P) 

provides  a standard immunity against white light required by the norm 

(up to 6000 Lux). The detector with a 

grey lens

 (JA-152P (G)) provides 

an  increased immunity against white light well above values required  

by the norm (up to 10 000 Lux). This lens helps to reduce false alarms 

caused by car lights, sunsets, lightning or reflective surfaces. False 

alarm immunity is  adjustable  to  two  levels. The detector has a pulse 

reaction (reports only its activation) and takes one position 

 

in the system. The detector should be installed by a trained technician 

with a valid certificate issued by an authorized distributor. 

This product 

is compatible with the JA-103K, JA-107K and subsequent control 

panels. 

Installation 

It is necessary to take into consideration that there should  

be no obstacles in the detector’s field of view which quickly change 

temperature (electrical  heaters, gas appliances, etc.), which move 

(curtains hanging above a radiator, robotic vacuum cleaners, etc.)  

or the movement of pets. Despite the detector being very immune  

to false alarms, it is not recommended to install the detector in places 

with intense air circulation (close to ventilators, air conditioning, vents, 

unsealed doors, etc.). There should be no obstacles in the detector’s 

field of view that would also obstruct its view into the guarded space. 

Figure 1.: 1 – LED indicators; 2 –PIR lens; 

3 – hole for locking screw; 4 – cover tab 

1. Open the detector cover by pressing the cover tab (4). Avoid

touching the PIR sensor inside (9) – you could damage it.

2. Take out the PCB – it is held by a tab on a lower part of the plastic.
3.  Prepare holes for screws on the rear part. The recommended

installation height is 2.5 m above the floor. For the proper detection 

of detector removal, it is necessary to also use holes on the segment 

for tamper detection. 

4. Insert  the PCB back  and proceed  according to the control panel

installation manual. Basic procedure:
a. The control panel must contain a JA-11xR radio module.
b. Go to the 

F-Link

  software, select the required position

in the 

Devices

  window and launch the enrollment mode

by clicking on the 

Enroll

 option.

c. Inserting the battery (mind the correct polarity)  will send

an enrollment signal to the control panel  and the detector will

be enrolled to the selected position.

d. This is followed by an up to three-minute detector stabilization

phase indicated by a red LED indicator (6) flashing

5. Close the detector cover. In order to comply with the norms,

the front cover must be secured with the supplied locking screw (3)

6. Configure the detector  by following the 

Detector internal settings

chapter in this manual 

Figure 2.: 5 – battery holder; 6 – LED indicators;  

7 – the JA-191PL external tamper connector; 8 – production code; 

9 – PIR sensor; 10 – cover tamper contact; 11 – antenna 

Notes:

 

The  detector  can also be enrolled into the system by entering its

production code in the F-Link software. You can find the production

code on the sticker (8)  placed inside the detector. All numbers

under the bar code must be entered (example: 1400-00-0000-

0001).

If you want to remove the detector from the system, erase it from its

position in the control panel.

Detector communication in the system 

The detector is equipped with bi-directional asynchronous 

communication with the JA-11xR radio module which enables changing 

the internal settings with ease (just as it is with BUS detectors) while 

taking into account the battery life time in normal operational mode. 

When the detector is enrolled into the system it works in a so-called 

accelerated 90-second mode

  until  Service mode is terminated 

 

(no longer than  24 h).  The detector performs a check every 90 s  

to monitor whether the control panel remains in Service mode, whether 

it should apply new settings or the LED indicator should indicate motion 

during a walk test. 

In the normal operational  mode  of the system,  the detector 

communicates periodically (it receives only regular reports, maximum 1x 

per  20 minutes). Therefore, it may take the detector up to 20 minutes  

to realize the control panel was switched to Service mode or to save 

changes made in the internal settings. This time can be shortened  

by triggering the detector which will switch it to the accelerated 90-

second mode immediately (moving in front of it, opening it = triggering 

the tamper contact). 

Important: 

When changes in the internal settings  are made, it is not necessary  

to wait 90 s (or 20 minutes) for the detector to confirm saving  

the changes. The control panel remembers such changes and transfers 

them to the detector the next time a periodical communication session 

occurs. 

Detector internal settings 

The detector settings  can be set in the 

Devices

  tab of the F-link 

software. Click on the 

Internal settings

 button at the detector’s position 

to open a dialogue window where you set 

(* indicates default settings):

 

External tamper sensor:

 

Disables*/Enables

 monitoring of an additional 

tamper contact of the JA-191PL jointed bracket. 

Immunity  level:

  Defines false alarm immunity. The 

Standard*

  level 

combines basic immunity with a rapid reaction. The 

Increased

  level 

provides higher immunity but the detector reaction is slower. 

Operational mode:

 

Smartwatch*

 is a setting intended for the permanent 

monitoring of movement in the guarded area. If a permanent movement  

is detected, three reports are sent every 20 s. The next report is then sent 

after 2 minutes. If the detector does not detect any movement for 10 minutes, 

the mode with three reports every 20 s is used again. The other available 

operational mode is 

One-minute interval

. The detector enters standby mode 

for 1 minute after it has detected movement. When the standby mode times 

out, the detector wakes up  and is ready to be triggered again.  When  

the battery is replaced the setting remains the same. 

Detector testing 

When in Service mode, the LED indicators indicate every movement. 

Upon leaving Service mode, the detector switches to an operational 

mode selected in the internal settings. Individual activations 

 

of the detector can also be monitored in the 

Diagnostics

  tab  

in the 

F-Link

 software. 

The LED indicators, including the yellow fault LED  indicator, are 

disabled in normal operational mode. 

Battery replacement 

The system automatically reports a low battery status. We recommend 

replacing the battery  within two weeks from the low battery report.  

It is done by a service technician in Service mode. 

Before inserting a  new battery, it is necessary to wait  for 10 s  

or to press the cover tamper contact (10) to consume the residual 

energy. 

Notes:

 

 

The detector immediately detects the  insertion of a low battery and

indicates it with the  yellow LED  indicator  flashing during

the stabilization period (min 15 s). 

 

The battery status can be monitored in the Diagnostics tab in the F-Link

software. 

 

To ensure proper functionality of the detector, we recommend using

the battery supplied by a distributor (BAT-3V0-CR123A) or other quality

lithium batteries. 

 

Do not discard the battery into the trash; dispose of it at a civic amenity

site. 