144 PROFIsafe
3
0
Safe_output_X114
_9_ctrl
State of the safe output X114:9 (see section
on page
). 1 = 24 V, 0 = 0 V.
1
Safe_output_X114
_8_ctrl
State of the safe output X114:8 (see section
on page
). 1 = 24 V, 0 = 0 V.
2
Safe_output_X114
_7_ctrl
State of the safe output X114:7 (see section
on page
). 1 = 24 V, 0 = 0 V.
3
Safe_output_X113
_9_ctrl
State of the safe output X113:9 (see section
on page
). 1 = 24 V, 0 = 0 V.
4
Safe_output_X113
_8_ctrl
State of the safe output X113:8 (see section
on page
). 1 = 24 V, 0 = 0 V.
5
Safe_output_x113
_7_ctrl
State of the safe output X113:7 (see section
on page
). 1 = 24 V, 0 = 0 V.
6
Negative_Scaling
Selects whether Variable SLS limit is scaled for negative
direction. 0 = Limit scaled, 1 = Limit not scaled (100%).
7
Positive_Scaling
Selects whether Variable SLS limit is scaled for positive
direction. 0 = Limit scaled, 1 = Limit not scaled (100%).
4
Variable_SLS_limit
_MSB
Safely-limited speed relative limit (MSB) [0.01%]
5
Variable_SLS_limit
_LSB
Safely-limited speed relative limit (LSB) [0.01%]
*)
If the PROFIsafe message includes a safety function request which is not supported or if the
safety function has not been configured, the FSO module activates the SSE function and
generates an FSO configuration fault (see chapter
Octet Bit Name
Description
Summary of Contents for FSO-12
Page 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 36: ...36 Safety information and considerations ...
Page 136: ...136 Safety functions ...
Page 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 200: ...200 PROFIsafe ...
Page 326: ...326 Start up ...
Page 386: ...386 Dimension drawings ...