Installation 215
5. Connect the supplied four-wire cable to the FSO terminal X111 and plug the other
end of the cable to the drive STO connection (XSTO connector). ABB
recommends to use the cable delivered with the FSO module. For a user-defined
cable, see section
STO cable and data cable between FSO module and drive
on
.
6. Connect the digital inputs, digital outputs, diagnostic pulses and signal ground at
the FSO terminals X113 and X114 according to the application requirements.
•
Use the tightening torque of 0.24 Nm (2.1 lbf·in).
•
Use proper cable strain relief.
•
Use only the I/O terminal blocks attached to the FSO module.
•
Make sure that the ground terminal maximum current is not exceeded. See
on page
.
5
6
5
6