Configuration 261
Related safety functions
The SLS1…4 functions use SAR1 parameters to monitor and/or define the
deceleration ramp (SLS with ramp monitoring). See section
page
The FSO module activates the STO function if the motor speed hits a ramp
monitoring limit during the deceleration ramp (SLS with ramp monitoring). See
section
on page
The FSO module activates the SSE function if the motor speed hits a trip limit. See
section
on page
.
= DI X113:2 &
X114:2
= DO X114:7
= Ramp
= Automatic
Remember to configure SAR1!
SLS2
Time
Speed
Input
Output
SLS activated
SLS monitoring started
= Version 1
= -1020 rpm
= 1200 rpm
= 1320 rpm
= -900 rpm