28 Safety information and considerations
Responsibilities
It is the responsibility of the machine builder / OEM / system integrator to make sure
that the essential health and safety requirements specified in the Machinery Directive
are met.
If you detect any failure in safety functions, contact your local ABB representative.
Intentional misuse
Use the FSO module according to the instructions given in the user’s manual. ABB is
not responsible for any damage caused by the misuse of the module.
The FSO module is not designed to protect a machine against intentional misuse or
sabotage.
Safety considerations
Warning!
In the stages of the product's life cycle when the safety option may
not provide protection, for example, during commissioning, system
maintenance, fault tracing, and decommissioning, user safety must be ensured
by other means.
Note:
After you initially start up the FSO module and also after you later modify any
application parameters or the configuration, you must check the safety of the entire
system by doing a verification according to the system safety verification plan and by
doing a validation of the correct operation of the safety application. See chapter
Response times
Safety function response time and FSO response times are specified in section
on page
.
The acceptable speed limits must be configured so that the speed cannot
accelerate/decelerate from an acceptable speed to a dangerous speed faster than
the response time of the FSO module.
FSO diagnostics
The FSO module performs extensive auto diagnostics tests during the runtime
operation on FSO internal parts as well as the communication and STO connection
between the FSO and the drive. The FSO goes into the Fail-safe mode if it detects a
fault.
• The communication between the FSO and the drive is diagnosed continuously.
• The STO connection between the FSO and the drive STO connector is diagnosed
during the power-up and periodically during the runtime.
Summary of Contents for FSO-12
Page 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 36: ...36 Safety information and considerations ...
Page 136: ...136 Safety functions ...
Page 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 200: ...200 PROFIsafe ...
Page 326: ...326 Start up ...
Page 386: ...386 Dimension drawings ...