Parameters 309
0.0…35880.0 rpm
Speed
SLSx.24 SLS2 output
Sets the digital output that is connected to
the output of the SLS2 function. Active when
SLS2 function is active and the motor speed
is below the SLS2 limit (that is, when the
SLS2 monitoring is on).
None
No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7
Single output X113:7
DO X113:8
Single output X113:8
DO X113:9
Single output X113:9
DO X114:7
Single output X114:7
DO X114:8
Single output X114:8
DO X114:9
Single output X114:9
SLSx.31 SLS3 input
Sets the digital input that is connected to the
secondary input of the SLS function with
limits 3.
None
No input connected
DI X113:1 & X114:1 Redundant input X113:1 & X114:1
DI X113:2 & X114:2 Redundant input X113:2 & X114:2
DI X113:3 & X114:3 Redundant input X113:3 & X114:3
DI X113:4 & X114:4 Redundant input X113:4 & X114:4
DI X113:1
Single input X113:1
DI X113:2
Single input X113:2
DI X113:3
Single input X113:3
DI X113:4
Single input X113:4
DI X114:1
Single input X114:1
DI X114:2
Single input X114:2
DI X114:3
Single input X114:3
DI X114:4
Single input X114:4
SLSx.32 SLS3 trip limit
negative
SLS3 negative speed limit that trips the
drive.
0.0 rpm
-35880.0 …0.0 rpm Speed
SLSx.33 SLS3 trip limit
positive
Sets the SLS3 positive speed limit that trips
the drive.
0.0 rpm
0.0…35880.0 rpm
Speed
Index
Name/Value
Description
Factory
default
Summary of Contents for FSO-12
Page 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 36: ...36 Safety information and considerations ...
Page 136: ...136 Safety functions ...
Page 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 200: ...200 PROFIsafe ...
Page 326: ...326 Start up ...
Page 386: ...386 Dimension drawings ...