PROFIsafe 145
ABB_PS1 profile F-Input user data
This table shows the bit order of the F-Input user data, which is included in the
PROFIsafe message sent from the FSO module to the safety PLC. For all the bits in
the F-Input data, one (1) means active and zero (0) non-active.
Note
: In the Fail-safe and Configuration states, all the bits in the PROFIsafe message
are set to “0”. In these cases, you can read the FSO state from:
• Siemens PLC: bits QBAD and PASS_OUT in the PROFIsafe data block
• ABB PLC: bit Device_Fault in the PROFIsafe data structure.
See also section
on page
Octet Bit Name
Description
0
0
SLS2_active
SLS2 (Safely-limited speed) is active. Active when the
SLS2 function is active and the motor speed is below the
SLS1 limit (that is, when the SLS2 monitoring is on).
1
SLS1_active
SLS1 (Safely-limited speed) is active. Active when the
SLS1 function is active and the motor speed is below the
SLS1 limit (that is, when the SLS1 monitoring is on).
2
Reserved
*)
The value is 0. Must be ignored by the F-Host.
3
Reserved
*)
The value is 0. Must be ignored by the F-Host.
4
SS1_active
SS1 (Safe stop 1) is function active.
5
SSE_active
SSE (Safe stop emergency) function is active.
6
SBC_active
SBC (Safe brake control) function is active.
7
STO_active
STO (Safe torque off) function is active.
1
0
Reserved
*)
The value is 0. Must be ignored by the F-Host.
1
Reserved
*)
The value is 0. Must be ignored by the F-Host.
2
Reserved
*)
The value is 0. Must be ignored by the F-Host.
3
Reserved
*)
The value is 0. Must be ignored by the F-Host.
4
SAR1_active
SAR1 (Safe acceleration range) is active.
5
SAR0_active
SAR0 (Safe acceleration range) is active.
6
SLS4_active
SLS4 (Safely-limited speed) is active. Active when the
SLS4 function is active and the motor speed is below the
SLS4 limit (that is, when the SLS4 monitoring is on).
7
SLS3_active
SLS3 (Safely-limited speed) is active. Active when the
SLS3 function is active and the motor speed is below the
SLS3 limit (that is, when the SLS3 monitoring is on).
Summary of Contents for FSO-12
Page 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 36: ...36 Safety information and considerations ...
Page 136: ...136 Safety functions ...
Page 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 200: ...200 PROFIsafe ...
Page 326: ...326 Start up ...
Page 386: ...386 Dimension drawings ...