Parameters 301
SSE.16 SSE ramp zero
speed delay for STO
Sets an extra delay time for the drive STO
(and SBC, if used) activation at the zero
speed limit in the SSE with emergency ramp
function.
With this parameter, the FSO module delays
the STO activation so that the drive is able to
reach the axle zero speed before the FSO
module activates the drive STO function.
The delay counter starts when the motor
speed reaches the zero speed limit
(parameter
). After this delay
has elapsed, the FSO module activates the
drive STO function. You can use this
parameter when the motor rotates a heavy
load (high inertia).
Note:
The FSO module activates the drive
STO immediately if the drive stops
modulating before this delay has passed
(that is, the motor actual speed reaches
0 rpm).
30,000 ms
0…30,000 ms
Time
SSE.21 SSE output
Sets the digital output that indicates the
activity of the SSE function. Active from the
SSE request until the function has been
acknowledged.
None
No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7
Single output X113:7
DO X113:8
Single output X113:8
DO X113:9
Single output X113:9
DO X114:7
Single output X114:7
DO X114:8
Single output X114:8
DO X114:9
Single output X114:9
SSE.22 SSE completed
output
Sets the digital output that indicates the
completion of the SSE function. See the
diagrams in section
None
No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7
Single output X113:7
Index
Name/Value
Description
Factory
default
Summary of Contents for FSO-12
Page 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 36: ...36 Safety information and considerations ...
Page 136: ...136 Safety functions ...
Page 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 200: ...200 PROFIsafe ...
Page 326: ...326 Start up ...
Page 386: ...386 Dimension drawings ...