352 Fault tracing
Event types
The FSO module generates three types of events to the drive:
• Pure events, which are just informative data
• Warnings, which are shown to the user
• Faults, which stop the drive and are shown to the user.
The user can select the event type (warning, fault or event) for certain function
requests, limit hits and special events:
• Parameter
defines the event type for the
STO, SS1 and SSE function external requests. The same parameter also defines
the event type that the FSO module generates when the function is completed.
• Parameter
defines the event type for the
limit hits of:
•
SLS1, …, SLS4, Variable SLS and SMS functions
•
ramp monitoring and time monitoring of the safety ramps SAR0 and SAR1.
• Parameter
SBUSGEN.10 STO indication passivation
defines the event type for
the FSO module passivation due to safety fieldbus problems.
Event code decoding with Drive composer Pro tool
Check the reason for the event from the event log of the Drive Composer tool by
keeping the mouse over the AUX-code. For additional information, see the table
below.
STO
The drive STO
circuit is closed
and the drive is
in operation.
Green
The drive STO
circuit is open.
-
-
FB
Safety
communication
to the fieldbus
has stopped.
Green
FSO is ready to
start safety
communication
to the fieldbus.
Green
Safety
communication to the
fieldbus is running.
LED
LED off
LED lit and steady
LED blinking
Summary of Contents for FSO-12
Page 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 36: ...36 Safety information and considerations ...
Page 136: ...136 Safety functions ...
Page 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 200: ...200 PROFIsafe ...
Page 326: ...326 Start up ...
Page 386: ...386 Dimension drawings ...