306 Parameters
SLSx.05 SLS ramp modoff
reaction
Selects the fault reaction in case the drive
modulation is lost during the SLS
deceleration ramp, when SLS is activated
from speed which is higher than SLS limit
speed.
Modoff
delay time
Modoff delay time
If drive modulation is lost during the SLS
deceleration ramp and the modulation does
not return within SLSx.06 time, FSO
activates STO.
Note:
If speed is below SLS limit (eg,
200.22), modoff is ignored.
Monitoring active
If drive modulation is lost during the SLS
deceleration ramp, SLS ramp or time
monitoring (SLSx.03) is kept on. Limit hit is
generated based on the last valid speed
estimate information of FSO.
Monitoring active
and modoff delay
time
Both Modoff delay time and Monitoring
active values are in use: FSO generates the
hit based on whichever condition is met first
and activates the STO.
Monitoring and
modoff delay time
are disabled
If drive modulation is lost during the SLS
deceleration ramp, FSO does not activate
STO. SLS indication (eg, SLSx.15) goes on
after STO.14 time has elapsed.
SLSx.06 SLS ramp modoff
delay time
Time to trip when modulation is lost.
Note:
SLSx.06 time must be set shorter than
STO.14, otherwise STO is not activated due
to limit hit when drive modulation is lost with
SLS function.
0 ms
0…3,600,000 ms
Time
SLSx.11 SLS1 input A
Sets the digital input that is connected to the
primary input of the SLS function with
limits 1.
None
No input connected
DI X113:1 & X114:1 Redundant input X113:1 & X114:1
DI X113:2 & X114:2 Redundant input X113:2 & X114:2
DI X113:3 & X114:3 Redundant input X113:3 & X114:3
DI X113:4 & X114:4 Redundant input X113:4 & X114:4
DI X113:1
Single input X113:1
DI X113:2
Single input X113:2
DI X113:3
Single input X113:3
DI X113:4
Single input X113:4
DI X114:1
Single input X114:1
Index
Name/Value
Description
Factory
default
Summary of Contents for FSO-12
Page 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 36: ...36 Safety information and considerations ...
Page 136: ...136 Safety functions ...
Page 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 200: ...200 PROFIsafe ...
Page 326: ...326 Start up ...
Page 386: ...386 Dimension drawings ...