Parameters 289
FSOGEN
General FSO parameters
FSOGEN.01 FSO general
settings version
Shows the version of the FSO general
parameter group (includes parameter
groups
and
and
Version 1
Version 1.
FSOGEN.11 Stop completed
output
Sets the digital output that indicates the
completion of any stop function. Active when
the FSO module has completed the STO,
SSE or SS1 function.
None
No input connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7
Single output X113:7
DO X113:8
Single output X113:8
DO X113:9
Single output X113:9
DO X114:7
Single output X114:7
DO X114:8
Single output X114:8
DO X114:9
Single output X114:9
FSOGEN.21 Motor nominal
speed
Sets the nominal motor speed.
100.0 rpm
1.0 …35880.0 rpm Speed
FSOGEN.22 Motor nominal
frequency
Sets the nominal motor frequency.
1.00 Hz
1.00…598.00 Hz
Frequency
Index
Name/Value
Description
Factory
default
Summary of Contents for FSO-12