206 Planning for installation
Safe brake control (SBC)
In this figure normal and safe brake controls are connected in series. Both are
independent and redundant 2-channel solutions.
The safe brake control needs a feedback from the brake system. The SBC feedback
can be from a relay/contactor or from the mechanical brake itself.
Note
: If also the drive can control the brake, the feedback must not be from the
mechanical brake.
1
10
9
8
7
6
5
4
3
2
X114
TP
DO
GND
DI
X113
M
Diagnostic pulses
DO
GND