ACH580 E-Clipse bypass and packaged drive user manual
213
Technical data
Standard enclosures – E-Clipse bypass drive with circuit breaker
Type Code
1
Nominal Output
Ratings
Frame
Size
UL (NEMA)
Type 1 Dim
Ref
UL (NEMA)
Type 12
(+B056) Dim
Ref
UL (NEMA)
Type 3R
(+B058)
Dim Ref
Current
A
Package
Power
HP
U
1
= 208 to 240V. Power ratings are valid at nominal output voltage U
N
= 208 V 60 Hz
ACH580-BxR-04A6-2
4.6
1
R1
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-06A6-2
6.6
1.5
R1
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-07A5-2
7.5
2
R1
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-10A6-2
10.6
3
R1
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-017A-2
16.7
5
R1
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-024A-2
24.2
7.5
R2
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-031A-2
30.8
10
R2
Bx1-2
Bx12-2
Bx3R-2
ACH580-BxR-046A-2
46.2
15
R3
Bx1-2
Bx12-2
Bx3R-2
ACH580-BxR-059A-2
59.4
20
R3
Bx1-2
Bx12-2
Bx3R-2
ACH580-BxR-075A-2
74.8
25
R4
Bx1-2
Bx12-2
Bx3R-2
ACH580-BxR-088A-2
88
30
R5
Bx1-3
Bx12-3
Consult
factory
ACH580-BxR-114A-2
114
40
R5
Bx1-3
Bx12-3
ACH580-BxR-143A-2
143
50
R6
Bx1-3
Bx12-3
ACH580-BxR-169A-2
169
60
R7
Bx1-3
Bx12-3
ACH580-BxR-211A-2
211
75
R7
Bx1-3
Bx12-3
ACH580-BxR-248A-2
248
100
2
R8
Bx1-3
Bx12-3
1) “BxR” represents BCR and BDR.
2) 100 HP @ 230V
Type Code
1
Nominal Output
Ratings
Frame
Size
UL (NEMA)
Type 1 Dim
Ref
UL (NEMA)
Type 12
(+B056) Dim
Ref
UL (NEMA)
Type 3R
(+B058)
Dim Ref
Current
A
Package
Power
HP
U
1
= 440 to 480V. Power ratings are valid at nominal output voltage U
N
= 460 V 60 Hz
ACH580-BxR-02A1-4
2.1
1
R1
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-03A0-4
3
1.5
R1
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-03A5-4
3.5
2
R1
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-04A8-4
4.8
3
R1
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-07A6-4
7.6
5
R1
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-012A-4
12
7.5
R1
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-014A-4
14
10
R2
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-023A-4
23
15
R2
Bx1-1
Bx12-1
Bx3R-1
ACH580-BxR-027A-4
27
20
R3
Bx1-2
Bx12-2
Bx3R-2
ACH580-BxR-034A-4
34
25
R3
Bx1-2
Bx12-2
Bx3R-2
ACH580-BxR-044A-4
44
30
R3
Bx1-2
Bx12-2
Bx3R-2
ACH580-BxR-052A-4
52
40
R4
Bx1-2
Bx12-2
Bx3R-2
ACH580-BxR-065A-4
65
50
R4
Bx1-2
Bx12-2
Bx3R-2
ACH580-BxR-077A-4
77
60
R4
Bx1-2
Bx12-2
Bx3R-2
Summary of Contents for ACH580 Series
Page 2: ......
Page 11: ...ACH580 BCR BDR VCR VDR E Clipse Bypass Drives 1 200 HP ...
Page 35: ...26 ACH580 E Clipse bypass and packaged drive user manual Installation ...
Page 43: ...34 ACH580 E Clipse bypass and packaged drive user manual Start up ...
Page 67: ...58 ACH580 E Clipse bypass and packaged drive user manual Application macros ...
Page 193: ...184 ACH580 E Clipse bypass and packaged drive user manual Fieldbus adapter ...
Page 207: ...198 ACH580 E Clipse bypass and packaged drive user manual Diagnostics ...
Page 229: ...220 ACH580 E Clipse bypass and packaged drive user manual Technical data ...
Page 231: ...ACH580 PCR PDR Packaged Drives with Disconnect 1 200 HP ...
Page 243: ...234 ACH580 E Clipse bypass and packaged drive user manual Installation ...
Page 256: ......