Chapter 3 Hardware Panels
GS1920v2 Series User’s Guide
40
3.2.2 Po we r C o nne c to r
Note: Make sure you are using the correct power source as shown on the panel.
To connect power to the Switch, insert the female end of the power cord to the AC power receptacle
on the rear panel. Connect the other end of the supplied power cord to a power outlet. Make sure that
no objects obstruct the airflow of the fans (located on the side of the unit).
See
Chapter 51 on page 398
for information on the Switch’s power supply requirements.
3.3 LEDs
After you connect the power to the Switch, view the LEDs to ensure proper functioning of the Switch
and as an aid in troubleshooting.
Table 4 LED Descriptions
LED
C O LO R
STATUS
DESC RIPTIO N
PWR
Green
On
The Switch is receiving power from the power module in the power slot.
Blinking
The Switch is returning to the last-saved custom default configuration settings.
Amber
On
The Switch is returning to its factory default configuration settings.
Off
The Switch is not receiving power from the power module in the power slot.
SYS
Green
On
The Switch is on and functioning properly.
Blinking
The Switch is rebooting and performing self-diagnostic tests.
Red
On
The Switch is functioning abnormally.
Off
The power is off or the Switch is not ready/malfunctioning.
CLOUD
Green
On
The Switch has successfully connected to the NCC (Nebula Control Center).
Blinking
The Switch cannot connect to the NCC because it is not registered.
Amber
On
The Switch is registered at NCC but cannot connect to the NCC. Please
check the Internet connection of the Switch.
Blinking
The Switch is not registered at NCC and cannot connect to the NCC. Please
check the Internet connection of the Switch and register the Switch at NCC.
Off
The Switch is operating in standalone mode. Nebula Control Center
Discovery is disabled in
Ba sic > C lo ud Ma na g e m e nt > Ne b ula C o ntro l C e nte r
Disc o ve ry
in the Switch Web Configurator.
LOCATOR
Blue
On
The Switch is uploading firmware. While the Switch is doing this, don’t turn off
the power.
Blinking
Shows the actual location of the Switch between several devices in a rack.
The default timer is 30 minutes when you are configuring the Switch.
Off
The locator is not functioning or malfunctioning.
Содержание GS1920-48HPv2
Страница 19: ...19 PA RT I Use r s Guide...
Страница 43: ...43 PA RT II T e c hnic al Re fe re nc e...
Страница 124: ...Chapter 9 VLAN GS1920v2 Series User s Guide 124 Figure 97 Advanced Application VLAN Port Based VLAN Setup Port Isolation...
Страница 155: ...Chapter 13 Spanning Tree Protocol GS1920v2 Series User s Guide 155 Figure 118 MSTP and Legacy RSTP Network Example...
Страница 193: ...GS1920v2 Series User s Guide 193 Figure 140 Classifier Example...
Страница 224: ...Chapter 24 Multicast GS1920v2 Series User s Guide 224 Figure 162 MVR Group Configuration Example 2 EXAMPLE...
Страница 367: ...Chapter 40 Access Control GS1920v2 Series User s Guide 367 Figure 271 Example Lock Denoting a Secure Connection EXAMPLE...
Страница 388: ...Chapter 48 Configure Clone GS1920v2 Series User s Guide 388 Figure 284 Management Configure Clone...