Chapter 24 Multicast
GS1920v2 Series User’s Guide
215
The following table describes the fields in the above screen.
24.4.4 MLD Sno o ping - pro xy Filte ring
Use this screen to configure the Switch’s MLD filtering settings. Click the
Filte ring
link in the
Adva nc e d
Applic a tio n
>
Multic a st > IPv6 Multic a st > MLD Sno o ping - pro xy
screen to display the screen as shown.
Table 88 Advanced Application > Multicast > IPv6 Multicast > MLD Snooping-proxy > Port Role Setting
LABEL
DESC RIPTIO N
MLD Snooping-proxy
VLAN ID
Select the VLAN ID for which you want to configure a port’s MLD snooping-proxy settings.
Port
This field displays the port number.
*
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row first
to set the common settings and then make adjustments on a port-by-port basis.
Changes in this row are copied to all the ports as soon as you make them.
Port Role
A port on the Switch can be either a
Do wnstre a m
port or
Upstre a m
port in MLD. A
downstream port connects to MLD hosts and acts as a multicast router to send MLD
queries and listen to the MLD host’s Report and Done messages. An upstream port
connects to a multicast router and works as a host to send Report or Done messages
when receiving queries from a multicast router.
Otherwise, select
No ne
if the port is not joining a multicast group or does not belong to
this VLAN.
Leave Mode
Select the leave mode for the specified downstream port(s) in this VLAN.
This specifies whether the Switch removes an MLD snooping membership entry (learned
on a downstream port) immediately (
Im m e dia te
) or wait for an MLD report before the
leave timeout (
No rm a l
) or fast leave timeout (
Fa st
) when an MLD leave message is
received on this port from a host.
Leave Timeout
Enter the MLD snooping normal leave timeout (in milliseconds) the Switch uses to update
the forwarding table for the specified downstream port(s).
This defines how many seconds the Switch waits for an MLD report before removing an
MLD snooping membership entry (learned on a downstream port) when an MLD Done
message is received on this port from a host.
Fast Leave Timeout
Enter the fast leave timeout (in milliseconds) for the specified downstream port(s).
This defines how many seconds the Switch waits for an MLD report before removing an
MLD snooping membership entry (learned on a downstream port) when an MLD Done
message is received on this port from a host.
Apply
Click
Apply
to save your changes to the Switch’s run-time memory. The Switch loses
these changes if it is turned off or loses power, so use the
Sa ve
link on the top navigation
panel to save your changes to the non-volatile memory when you are done configuring.
Cancel
Click
C a nc e l
to reset the fields to your previous configuration.
Содержание GS1920-48HPv2
Страница 19: ...19 PA RT I Use r s Guide...
Страница 43: ...43 PA RT II T e c hnic al Re fe re nc e...
Страница 124: ...Chapter 9 VLAN GS1920v2 Series User s Guide 124 Figure 97 Advanced Application VLAN Port Based VLAN Setup Port Isolation...
Страница 155: ...Chapter 13 Spanning Tree Protocol GS1920v2 Series User s Guide 155 Figure 118 MSTP and Legacy RSTP Network Example...
Страница 193: ...GS1920v2 Series User s Guide 193 Figure 140 Classifier Example...
Страница 224: ...Chapter 24 Multicast GS1920v2 Series User s Guide 224 Figure 162 MVR Group Configuration Example 2 EXAMPLE...
Страница 367: ...Chapter 40 Access Control GS1920v2 Series User s Guide 367 Figure 271 Example Lock Denoting a Secure Connection EXAMPLE...
Страница 388: ...Chapter 48 Configure Clone GS1920v2 Series User s Guide 388 Figure 284 Management Configure Clone...