Chapter 34 OAM
GS1920v2 Series User’s Guide
312
Discovery state This field indicates the state in the OAM discovery process. OAM-enabled devices use this
process to detect each other and to exchange information about their OAM configuration
and capabilities. OAM discovery is a handshake protocol.
Fa ult
: One of the devices is transmitting OAM PDUs with link fault information, or the interface is
not operational.
Ac tive Se nd Lo c a l
: The port is in active mode and is trying to see if the remote device supports
OAM.
Pa ssive Wa it
: The port is in passive mode and is waiting for the remote device to begin OAM
discovery.
Se nd Lo c a l Re m o te
: This state occurs in the following circumstances.
•
The port has discovered the remote device but has not accepted or rejected the
connection yet.
•
The port has discovered the remote device and rejected the connection.
Se nd Lo c a l Re m o te O K
: The port has discovered the remote device and has accepted the
connection. In addition, the remote device has not accepted or rejected the connection
yet, or the remote device has rejected the connected.
Se nd Any
: The port and the remote device have accepted the connection. This is the
operating state for OAM links that are fully operational.
Remote Client
MAC address
This field displays the MAC address of the IEEE 802.3ah-enabled remote Ethernet device that is
connected to the Switch.
Vendor(oui)
This field displays the Organizationally Unique Identifiers (OUI) representing the vendor of the
IEEE 802.3ah-enabled remote Ethernet device that is connected to the Switch.
Statistics
This section displays the number of OAM packets transferred on the port of the Switch.
Information
OAMPDU Tx
This field displays the number of OAM PDUs sent on the port.
Information
OAMPDU Rx
This field displays the number of OAM PDUs received on the port.
Event Notification
OAMPDU Tx
This field displays the number of unique or duplicate OAM event notification PDUs sent on the
port.
Event Notification
OAMPDU Rx
This field displays the number of unique or duplicate OAM event notification PDUs received on
the port.
Loopback Control
OAMPDU Tx
This field displays the number of loopback control OAM PDUs sent on the port.
Loopback Control
OAMPDU Rx
This field displays the number of loopback control OAM PDUs received on the port.
Variable Request
OAMPDU Tx
This field displays the number of OAM PDUs sent to request MIB objects on the remote device.
Variable Request
OAMPDU Rx
This field displays the number of OAM PDUs received requesting MIB objects on the Switch.
Variable Response
OAMPDU Tx
This field displays the number of OAM PDUs sent by the Switch in response to requests.
Variable Response
OAMPDU Rx
This field displays the number of OAM PDUs sent by the remote device in response to requests.
Table 145 Advanced Application > OAM Status > OAM Details (continued)
LABEL
DESC RIPTIO N
Содержание GS1920-48HPv2
Страница 19: ...19 PA RT I Use r s Guide...
Страница 43: ...43 PA RT II T e c hnic al Re fe re nc e...
Страница 124: ...Chapter 9 VLAN GS1920v2 Series User s Guide 124 Figure 97 Advanced Application VLAN Port Based VLAN Setup Port Isolation...
Страница 155: ...Chapter 13 Spanning Tree Protocol GS1920v2 Series User s Guide 155 Figure 118 MSTP and Legacy RSTP Network Example...
Страница 193: ...GS1920v2 Series User s Guide 193 Figure 140 Classifier Example...
Страница 224: ...Chapter 24 Multicast GS1920v2 Series User s Guide 224 Figure 162 MVR Group Configuration Example 2 EXAMPLE...
Страница 367: ...Chapter 40 Access Control GS1920v2 Series User s Guide 367 Figure 271 Example Lock Denoting a Secure Connection EXAMPLE...
Страница 388: ...Chapter 48 Configure Clone GS1920v2 Series User s Guide 388 Figure 284 Management Configure Clone...