Start-up
.
60 | CTW900
2.
Set the acceleration (P0100) and deceleration (P0101) times according to the application. Path to
access P0100 and P0101: Menu
01 PARAMETER GROUPS
21 Ramps.
3.
Monitor with the oscilloscope the Analog Output 1 (XC1:7 and 8) configured as ‘Effective Speed’
(P0251 = 3).
4.
Enable the firing of the armature (close the ‘General Enable’ switch) and apply the ‘Run’ command.
5.
Check the measured signal:
Figure 6.6
– Wave form for the “Effective Speed” analog output in the setting of the speed regulator
6.
Set P0159 and P0160 until obtaining a wave form similar to that shown in Figure 6.6
b)
. Path to access
P0159 and P0160: Menu
01 PARAMETER GROUPS
26 REGULATORS
100 Speed Reg.
6.4.4
Optimization of the Field Regulator
1.
Monitor with the oscilloscope the “IF” test point on the IC900 electronic interface board.
2.
Enable the firing of the armature (‘General Enable’ switch = closed) and check the stability of the signal.
3.
If the signal is not stable, vary the Field Proportional Gain (P0175) and/or Field Integral Gain (P0176).
Path to access P0175 and P0176: Menu
01 PARAMETER GROUPS
26 REGULATORS
102
Field Reg.
6.4.5
Optimization of the EMF Regulator
The optimization of the EMF regulator is only needed for motors that operate in the field weakening area.
Normally the factory settings are enough for most applications. However, if the motor deceleration is too slow
(not responding to the value set in P0101), it is recommended to increase the EMF Proportional Gain (P0186).
Path to access P0186: Menu
01 PARAMETER GROUPS
26 REGULATORS
103 EMF Reg.