Detailed Description of the Parameters
.
CTW900 | 129
P0006 – Converter Status
Adjustable Range:
0 = Disabled
Factory Setting:
1 = Ready
2 = Run
3 = Undervoltage
4 = Fault
5 = Self-Tuning
6 = Configuration
7 = Blocked
8 = Up Ramp
9 = Down Ramp
Properties:
RO
Groups of
09 READ ONLY PARAMETERS
Access via HMI:
Description:
It indicates one of the ten possible status of the CTW900. See the description of each status in the following
table.
Table 7.26
–Description of the status of the CTW900
Status
Description
Disabled
Indicates the converter is energized and without faults, but without the General Enable
command.
Ready
Indicates the converter is enabled and with the field excited, ready to produce torque.
Run
Indicates the converter is running in the programmed reference.
Undervoltage
Indicates the converter has a insufficient voltage for the operation and it will not accept the
enable command.
Fault
Indicates the converter is in the fault status.
Self-Tuning
Indicates the converter is executing the self-tuning routine (function not implemented).
Configuration
Indicates the converter is in the Oriented Start-up routine or with incompatible parameter
setting (see Table 7.27).
Blocked
Indicates the converter is disabled by the Stop Logic function.
Up Ramp
Indicates the converter is executing the acceleration ramp.
Down Ramp
Indicates the converter is executing the deceleration ramp.
The converter status is also shown on the upper left corner of the keypad (see Figure 4.6). In some status,
however, the status is shown abbreviated due to space.
P0007 – Armature Voltage
Adjustable Range:
-2000 to 2000 V
Factory Setting:
Properties:
RO
Groups of
09 READ ONLY PARAMETERS
Access via HMI:
Description:
It indicates the present output voltage (A1/B2) for the motor armature circuit in Volts (V).
P0008 – Field Current
Adjustable Range:
0.0 to 55.0 A
Factory Setting:
Properties:
RO
Groups of
09 READ ONLY PARAMETERS
Access via HMI:
Description:
It indicates the current of the motor field circuit in Amps (A).
P0009 – Motor Torque
Adjustable Range:
-1000.0 to 1000.0 %
Factory Setting:
Properties:
RO
Groups of
09 READ ONLY PARAMETERS
Access via HMI:
Description:
It indicates the torque developed by the motor in relation to its armature rated current (P0401).