Detailed Description of the Parameters
.
CTW900 | 91
Example: In case the sequence
10100010
is displayed on the keypad (HMI), it will correspond to the following
status of the DIs:
Table 7.13
– Status of the digital inputs
DI8
DI7
DI6
DI5
DI4
DI3
DI2
DI1
Active
(+24 V)
Inactive
(0 V)
Active
(+24 V)
Inactive
(0 V)
Inactive
(0 V)
Inactive
(0 V)
Active
(+24 V)
Inactive
(0 V)
P0263 – Input DI1 Function
P0264 – Input DI2 Function
P0265 – Input DI3 Function
P0266 – Input DI4 Function
P0267 – Input DI5 Function
P0268 – Input DI6 Function
P0269 – Input DI7 Function
P0270 – Input DI8 Function
Adjustable Range:
0 = Not used
Factory Setting:
P0263 = 2
1 = Run/ Stop
P0264 = 1
2 = General Enable
P0265 = 8
3 = Quick Stop
P0266 = 0
4 = Forward Run
P0267 =14
5 = Reverse Run
P0268 = 10
6 = 3-Wire Start
P0269 = 0
7 = 3-Wire Stop
P0270 = 0
8 = FWD/REV
9 = Local/ Remote
10 = JOG
11 = Increase E.P.
12 = Decrease E.P.
13 = Multispeed
4
14 = 2nd Ramp
15 = Speed/Torque
16 = JOG+
17 = JOG-
18 = Without External Alarm
19 = Without External Fault
20 = Reset
21 = Speed Regulator Gains
22 = Paramet. Off
23 = Load User 1/2
24 = Load User 3
25 = Trace Function
Properties:
CFG1
Groups of
01 PARAMETER GROUPS or 07 I/O CONFIGURATION
Access via HMI:
34 Digital Inputs
........
34 Digital Inputs
........
Description:
These parameters allow configuring the digital input function, according to the related adjustable range.
For further details about the form of actuation of the digital inputs, refer to Figure 7.14 and/or the notes below.
Run/Stop:
In order to ensure the proper operation of this function, it is necessary to set P0224 and/or P0227 to
1.
Local/Remote:
When set, this functions actuates in “Local” with the application of 0V to the input, and in
“Remote” with the application of +24V. It is also necessary to set P0220=4 (DIx).
4
Option available only in parameter P0266, P0267 and P0268 (DI4, DI5 and DI6).