Quick Parameter Reference
.
18 | CTW900
Param.
Function
Adjustable Range
Factory
Setting
User’s
Setting
Proper.
Groups
Page
P0319
Copy Function HMI
0 = Inactive
0
CFG1
06
123
1 = Drive -> HMI
2 = HMI -> Drive
P0340
Auto-Reset Time
0 to 600 s
0 s
38
108
P0348
Overload Protection Config.
0 = Inactive
1
CFG1
38
109
1 = Fault/ Alarm
2 = Fault
3 = Alarm
P0349
Ixt Alarm Level
70 to 100 %
85 %
CFG1
38
109
P0350
Ia > Ix Detector Config.
0 = Active
0
38
110
1 = Except Accel/Brake
P0352
Tacho Fault Protection
0 = Active
0
CFG1
38
110
1 = Inactive
P0353
EMF Level Tacho Fault
0 to 1000 V
50 V
CFG1
38
110
P0354
Speed Diff. Tacho Fault
0 to 100 %
25 %
CFG1
38
110
P0355
Torque for Stall Protection
0 to 100 %
5 %
CFG1
38
111
P0356
Delay Field Missing
0.1 to 10.0 s
2.0 s
CFG1
38
111
P0357
Line Phase Loss Time
0 to 60 s
3 s
38
111
P0358
Max. Armature Overvoltage
0 to 100 %
10 %
38
111
P0359
Max. Field Overcurrent
0 to 35 %
10 %
38
112
P0361
Max. Line Overvoltage
0 to 30 %
15 %
CFG1
38
112
P0362
Line Undervoltage Level
0 to 30 %
20 %
CFG1
38
112
P0363
Max. Line Unbalance
0 to 30 %
15 %
CFG1
38
113
P0364
Max. Line Freq. Variation
1 to 10 %
5 %
CFG1
38
113
P0400
Armature Rated Voltage
0 to 1200 V
400 V
CFG1
37
105
P0401
Armature Rated Current
0 to 3500 A
50 A
CFG1
37
106
P0402
Motor Rated Speed
10 to 6500 rpm
1800 rpm
CFG1
37
106
P0404
Field Rated Current
0.2 to 50.0 A
1.2 A
CFG1
37
106
P0405
Encoder Pulses Number
100 to 9999 ppr
1024 ppr
CFG1
24
71
P0406
Tacho Voltage 1000 rpm
0.0 to 300.0 V
60.0 V
CFG1
24
72
P0407
DC Tacho Gain Adjustment
0.000 to 1.999
1.000
24
72
P0409
Armature Resistance
0.000 to 0.999 ohm
0.000 ohm
37
106
P0550
Trace Trigger Signal Source
0 = Not selected
0
41
116
1 = Total Reference
2 = Current Speed
3 = Armature Current
4 = Armature Voltage
5 = Field Current
6 = Motor Torque
7 = AI1
8 = AI2
9 = AI3
10 = AI4
P0551
Trace Trigger Level
-100.0 to 150.0 %
0.0 %
41
116
P0552
Trace Trigger Condition
0 = P0550* = P0551
5
41
117
1 = P0550* <>P0551
2 = P0550* > P0551
3 = P0550* < P0551
4 = Alarm
5 = Fault
6 = DIx
P0553
Trace Sampling Period
1 to 65535
1
41
117
P0554
Trace Pre-Trigger
0 to 100 %
0 %
41
117