Seq.
Action/Result
Indication on the display
Seq.
Action/Result
Indication on the display
1
- Monitoring Mode
- Press
“Menu”
(left soft
key).
8
- Change the content of
P0201 (
Language
) and
P0202 (
Speed Feedback
Selection
) if necessary.
2
- The group “
00 ALL
PARAMETERS
” is
selected.
- Press
“
”
until selecting
the group
“02 ORIENTED
START-UP”
.
9
- Set the value of P0296
(
Line Rated Voltage
) and
P0297 (
Field Control
Loop
) according to the
line and application.
3
- The group
“02
ORIENTED START-UP”
is then selected.
- Press
“Select”
.
10
- Choose the
Control
Mode
in P0299 and the
Armature Rated Voltage
in P0400.
4
- The
“Oriented Start-up”
is already selected.
- Press
“Select”
.
11
- Configure the
Armature
Rated Current
in P0401
and the
Motor Rated
Speed
in P0402.
5
- The content of
“P0317
= [000] No”
is displayed.
- Press
“
”
.
12
- Set the value of the
Field Rated Current
(P0404) and the
Number
of Encoder Pulses
(P0405) according to the
application.
Note: Parameter P0405
will only be displayed if
the accessory board
ENC-01 or ENC-02 is
connected to the
converter.
6
- The content of the
parameter changes to
“P0317 = [001] Yes”
.
- Press
“Save”
.
13
- Change, if necessary,
the value of the
Tacho
Voltage for 1000 rpm
(P0406) and of the
Armature Resistance
(P0409).
- In order to finish the
Oriented Start-up routine,
press
“Reset”
(left soft
key) or
.
7
- At this moment, the
Oriented Start-up routine
starts and the “Config”
status is displayed on the
upper left corner of the
keypad (HMI).
- The parameter
“Maximum Speed”
is
already selected.
- If necessary, change it to
another value, according
to the application, by
pressing
“Selec.”,“
”
or
“
”
and then
“Save”
.
- Also set the value of the
Field Minimum Current
(P0177) according to the
motor.
14
- After some seconds,
the display returns to the
Monitoring Mode.
Figure 6.2
– Sequence of the Oriented Start-up routine
Содержание CTW900
Страница 2: ......
Страница 52: ...Installation and Connection 52 CTW900 Figure 5 16 Connections in XC1 for configuration 4...
Страница 69: ...Detailed Description of the Parameters CTW900 69 Figure 7 3 Block diagram of the speed reference...
Страница 135: ...Detailed Description of the Parameters CTW900 135 Figure 7 21 Block diagram of the control of the CTW900...