Detailed Description of the Parameters
.
68 | CTW900
P0122 – Speed Reference for JOG
Adjustable Range:
0 to 10000 rpm
Factory Setting:
150 rpm
Properties:
Groups of
01 PARAMETER GROUPS
...
Access via HMI:
22 Speed References
...............
Description:
During the JOG command, the motor accelerates up to the value defined in P0122, following the acceleration
ramp set.
The command source of JOG is defined in parameters P0225 (Local Status) or P0228 (Remote Status).
If the command source of JOG is set for Digital Input (P0225/P0228=DIx), the selected input must be set for the
“JOG” function (P0263...P0270 = 10) so that the command can be accepted.
For further details, refer to figures 7.3 and 7.9.
Notes:
■
The direction of rotation is defined by parameters P0223 or P0226;
■
The JOG command is only effective with the motor stopped;
■
For the “JOG+” option, check the description of the following parameter.
P0122 – Speed Reference for JOG+
P0123 – Speed Reference for JOG-
Adjustable Range:
0 to 10000 rpm
Factory Setting:
150 rpm
Properties:
Groups of
01 PARAMETER GROUPS
...
Access via HMI:
22 Speed References
...............
Description:
The JOG+ and JOG
−
commands are always done via digital inputs. Therefore, the selected inputs must be set
for the “JOG+” and “JOG
−
” functions, as presented in Table 7.3 below:
Table 7.3
– Selection of the JOG+ or JOG- command via digital input
Digital Input
Function
JOG+
JOG
DI1
P0263=16 P0263=17
DI2
P0264=16 P0264=17
DI3
P0265=16 P0265=17
DI4
P0266=16 P0266=17
DI5
P0267=16 P0267=17
DI6
P0268=16 P0268=17
DI7
P0269=16 P0269=17
DI8
P0270=16 P0270=17
During the JOG+ and JOG- commands, the values of P0122 and P0123 are respectively added to or
subtracted from the speed reference in order to generate the total reference (check representation in Figure
7.3).
P0163 – Local Reference Offset
P0164 – Remote Reference Offset
Adjustable Range:
–999 to 999
Factory Setting:
0
Properties:
Groups of
01 PARAMETER GROUPS
...
Access via HMI:
22 Speed References
...............
Description:
Set the speed reference offset of the analog inputs (AIx). Refer to Figure 7.3.
Содержание CTW900
Страница 2: ......
Страница 52: ...Installation and Connection 52 CTW900 Figure 5 16 Connections in XC1 for configuration 4...
Страница 69: ...Detailed Description of the Parameters CTW900 69 Figure 7 3 Block diagram of the speed reference...
Страница 135: ...Detailed Description of the Parameters CTW900 135 Figure 7 21 Block diagram of the control of the CTW900...