DK424i Installation
Step 6: Install Universal and Processor PCBs
7-40
Strata DK I&M 6/00
♦
Install universal slot PCBs per the DK424i configuration guidelines (see
DK424i Cabinet Slot Configuration” on Page 6-27
♦
Install the metal mesh shield, B50MT around the 25-pair cables connected to PCBs per
.
PCB Installation Considerations
The Base Cabinet has ten slots. The first two slots, labeled “B101” and “B102” are reserved for the
common control unit and future feature upgrades. The next eight slots (labeled “S101” ~“S108”)
are universal and capable of hosting any of the station, line, and option interface PCBs compatible
with the DK424i systems.
The Expansion Cabinets have ten universal slots, labeled “S_01,” “S_02,” etc., where the blank
space of the label represents the number of the Expansion Cabinet. Like the universal slots in the
Base Cabinet, these universal slots are capable of hosting any of the station, line, and option
interface PCBs (except RSIU which can only be installed in slot S101 of the Base Cabinet).
Cabinets are numbered from 1 to 5. The Base Cabinet is numbered 1; the first Expansion Cabinet,
number 2; the second Expansion Cabinet, number 3, etc. See the DK424i Configuration and
Universal Slot PCB section for details regarding PCB installation.
PCB Option Considerations
DK424i PCBs can be configured for a variety of hardware and software options. Hardware options
are defined as either internal (generally related to optional PCB subassemblies) or external (related
to connection of peripheral equipment such as background music, voice mail, etc.).
Hardware Options
Some PCBs must be configured for hardware options prior to installation of the PCB in the
cabinet. Configuration instructions for internal hardware options are provided in the individual
PCB installation procedures in this chapter and in
Chapter 9 – Universal Slot PCBs
. Configuration
instructions for external hardware options are provided in Chapter 12 – Peripheral Installation.
Software Options
PCBs are configured for software options through programming, following the installation
instructions of the PCBs. A programming overview for each PCB is provided in the individual
PCB installation procedures in this chapter. Refer to the
Strata DK Programming Manual
for
detailed programming instructions.
Содержание Strata AirLink DK40i
Страница 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Страница 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Страница 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Страница 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Страница 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Страница 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Страница 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Страница 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Страница 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...