DK14 Installation
KSU Mounting Considerations
Strata DK I&M 6/00
1-7
DK14 Installa
ti
on
Figure 1-6
DK14 Side View and Jack Locations
Reserve Power Battery
A second HPFB can be installed directly above the unit to supply backup reserve power.
➤
To install the Reserve Power Battery and Charger (HPFB)
1. Place the HPFB directly above the DK14 KSU (
).
2. Mark the location of the two screw holes, then drill holes.
3. Screw the two screws two-thirds into the mounting surface.
4. Hang the HFPU on the screws then tighten the screws into the mounting surface.
5. Plug the first HPFB connector into BATT connector on the right side of the KSU.
6. Connect a ground wire from the HPFB “FG” screw to the DK14 QPSU8 screw labeled
“HPFB6.” The ground wire can be fed through the opening by the AC power cord.
Note
The DK14 should be plugged into AC power and the DC power switch should be turned
On. The HFPU will not start to operate if AC power is not available during the initial
installation.
7. The 24VDC LED on the HPFB should light. If it does not light, press the battery Off switch
with a pencil point or other small-tipped object.
8. Dress and tie-wrap the HPFB cables.
O
—
AC Power Cord
and Plug 4' 7"
Station
Tip/Ring
Amphenol
25-pair Jack
(female)
Left Side View
Right Side View
RJ11 CO
Line Jacks
RS-232
Interface
Jacks, TTY,
Caller ID,
SMDR
DC ON/OFF
Power Switch
Reserve
Battery (HPFB)
Connector
RJ11 Power
Failure
Transfer Jack
BATT
DC
SI01
SI02
Tie-wrap supplied
to Hold Amphenol
Connector
CO4
CO2
CO1
CO3
PFT
To HPFB FG
Screw
3"
2397
Tie-wrap Holder
Tie-wrap
Holder
Содержание Strata AirLink DK40i
Страница 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Страница 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Страница 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Страница 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Страница 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Страница 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Страница 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Страница 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Страница 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...