ISDN Interfaces
ISDN Testing and Troubleshooting
Strata DK I&M 6/00
16-37
ISDN
Inte
rface
s
4. Setup the com-port parameters for 7-bits, even parity, 1-stop bit and the appropriate speed.
Figure 16-29 DK TTY Port BRI Connection to PC
5. Press the Enter key on the PC keyboard
The DK responds with
CODE
6. At the CODE prompt, type the DK, 4-digit code (Program 00 code) from the PC keyboard
The DK responds with
MODE
7. At the MODE prompt, type
TEST
and press Enter from the PC keyboard
The DK responds with
T
Note
Make all entries from the PC keyboard in Capital letters.
8. At the T prompt, type
LBUU ss m
and press
Enter
from the PC keyboard
Where ss=BRI PCB slot number and m=BRI circuit number (1-4).
Notes
●
The U-terminal must be idle, and remain idle, during the loop back test.
●
The DK sends 4 octets of data to the U-terminal during the loop back test: 0X00, 0XFF, 0XB2,
and 0X4D. These octets are sent to the B1, B2, and D channels 50 times. If the DK receives
80% of the sent data back, it assumes the test to pass. (i.e., the U-terminal and wiring is good.)
If The DK responds with:
## BUU LOOP BACK TEST ##
SLOT=ss CIRCUIT=m B1:OK B2:OK D:OK
4733
DK System
RBUU
(LT Mode)
PC with Hyper
Terminal
Software
U-Terminal
device
(loop back)
1-pair BRI Circuit Line Cord
3-pair Telephone Cord
RSIU or PIOU
TTY Port
TTY Port
Test data from DK sent to Terminal.
If 80% of sent data is returned test
passes.
Содержание Strata AirLink DK40i
Страница 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Страница 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Страница 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Страница 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Страница 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Страница 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Страница 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Страница 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Страница 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...