ISDN Interfaces
Timing and Synchronization
Strata DK I&M 6/00
16-41
ISDN
Inte
rface
s
RPTU Performance Monitoring
The performance of the RPTU can be monitored using the Data Dump Mode. This requires:
♦
RSIU, RSIS, PIOU, PIOUS or TSIU PCB TTY port.
♦
ASCII terminal or PC with communications software (such as ProComm).
♦
IMDU or RMDS modem or Hayes compatible modem for remote monitoring.
The RPTU monitoring feature provides a download of PRI errors detected as shown in
. This data can be stored to a file and/or printed when using a PC with communications
software.
There are no time parameters for the error report, so the time between error-count increments must
be monitored manually. The counter is reset after 15 registrations and begins again from zero.
Basically the error count of any error category should not increase within 24-hour periods.
➤
To dump the data (PRI ERROR DISPLAY) from a terminal or PC (local or remote)
1. Establish communications between the DK TTY port and the terminal or PC using a
communications software.
2. Enter the security code, and press
Enter
(or
Return
).
3. At the
>MODE
prompt, type
DUMP
(must be all caps), and press
Enter
(or
Return)
. The
>D
prompt displays on your screen.
4. At the
>D
prompt, type
PRIERR
and press
Enter
(or
Return
). The display (see
) shows all RPTU PCBs (PRI NO=1~PRI NO=8), even if the associated RPTU (1~8) is
not installed. The ERROR counter can only be reset by turning the DK Off and On.
➤
To exit the dump mode
➤
At the
>D
prompt, type
QUIT
, press
Enter
(or
Return
); the
>MODE
prompt displays.
Содержание Strata AirLink DK40i
Страница 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Страница 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Страница 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Страница 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Страница 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Страница 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Страница 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Страница 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Страница 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...