DK424i Configuration
Primary/Reserve Power Cabinet Hardware
6-40
Strata DK I&M 6/00
Primary/Reserve Power Cabinet Hardware
The lightweight and compact design enables easy wall or floor mounting. The BFIF hardware kit
is needed for floor mounting. If floor mounting three or more cabinets, AC and reserve power must
be connected to the BCCB conduit connection box option by a licensed electrician. If more than
two cabinets require reserve power batteries, the BBDB must be installed. Wall mounting the
system does not require special hardware.
Underwriters’ Laboratory (UL) and local electrical codes require certain standards for connecting
commercial AC and reserve power to the Strata DK424i system.
describes which
assemblies may be required to meet UL and local electrical code standards.
Table 6-28
Power Cabinet Hardware
Option
Description
BPSU672
DK424i cabinet power supply. This power supply can operate with 120VAC, 208VAC, or 240VAC
connected as the system’s primary AC power source. It automatically detects and adjusts to the
type of primary AC power that is connected. The power supply is included with each cabinet
ordered but must be installed in the field.
Standard 9 ft. AC
power cords with AC120VAC/15A plugs are provided with DK424i Base or
Expansion cabinets. When AC208V or AC240V power is used, a special AC cord, BACL240, is
required for each cabinet power supply and must be ordered separately.
RPSB2
Cabinet power strip for 120VAC primary power – provides three standard 120VAC/15A outlets
(NEMA5-15R) and nine ft. AC power cord with standard 120VAC/15A plug (NEMA5-15P). This
unit is field installed inside system cabinet side panels. The system can use 12 amps. (max.).
One RPSB2 is required for two cabinet systems if the local electric code allows only one AC
power cord to be connected to the system.
Note
If the local electric code allows only one AC power cord to be connected to the system,
208VAC or 240VAC must be used as primary AC power for systems with four or more
cabinets.
One RPSB2 is required for a three or four cabinet system if the local electric code allows two AC
power cords connected to the system.
Two RPSB2s are required for a five cabinet system if the local electric code allows two AC power
cords connected to the system.
BPSB240
Cabinet power strip for 208VAC or 240VAC primary power. Provides three 240VAC/20A outlets
(NEMA 6-20R) and 9ft. AC power cord with a standard 240VAC/20A plug (NEMA 6-20P). This
unit is field installed inside system cabinet side panels. The system can use 16 amps. (max.).
One BPSB240 is required for two or three cabinet systems.
Two BPSB240s are required for four or five cabinet systems.
Notes
♦
Local electric codes allow only one AC power cord to be connected to the system when
using 208VAC or 240VAC as the primary AC power.
♦
If using 208VAC as primary power, the plug on the BPSB240 AC power cord (NEMA
6-20P) may have to be changed by a certified electrician depending on local electric
codes.
Содержание Strata AirLink DK40i
Страница 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Страница 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Страница 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Страница 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Страница 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Страница 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Страница 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Страница 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Страница 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...