Peripheral Installation
PC/Data Communications Interface Units
12-58
Strata DK I&M 6/00
DIP Switch Options
The RPCI-DI, PDIU-DI and the PDIU-DS each have a four-control DIP switch which can be
configured for signaling options. The switch is located on the bottom of the PDIU-DI, and on the
back panel of the PDIU-DS (see
SW1-1
Normally, this switch is set On to disconnect devices from RPCIs or DIUs automatically. The
connection is maintained if data is exchanged between the device and the RPCI or DIU within
eight to nine minute intervals. If SW1-1 is Off on the called and calling DIU, data calls will remain
connected until released manually.
SW1-2
This switch is placed in the On position when the RPCI-DI or PDIU-DI (or PDIU-DS configured
like a DCE) must hold DCD and DSR On continuously. If SW1-2 is Off, DSR follows DTR and
DCD will be On only when the DIU is connected on a data call to another DIU. SW1-2 should be
Off on a RPCI DIU when it is connected to a personal computer that uses a communications
software program to establish data calls with AT commands; and whenever PDIU-DS is connected
to a modem.
SW1-3
The RPCI-DI or PDIU-DI (or PDIU-DS configured as a DCE) sends the Ring Indicate (RI) signal
to the computer to tell the computer (DTE) that the RPCI or PDIU is receiving an incoming call.
SW1-3 should be On for the DIU to send RI steady, and Off to send at one second On/three
seconds Off intervals.
SW1-4
This switch is placed in the On position if the computer does not output the RTS signal or when
connected to a modem that tracks the DCD signal (modem set with AT&C1). Sometimes, the DTE
device may use RTS/CTS for Ready/Busy flow control, in these cases SW1-4 should be Off.
In this case the DCD signal of the calling DTE is used as the RTS lead of the called DTE and the
DCD signal of the called DTE is used as the RTS signal of the other DTE. In this case a signal
which stops the DTE from transmitting data (usually the CTS lead) should be cross-connected to
the RPCI’s or DIU’s DCD signal. Consult the DTE device or application software documentation
to determine which type of flow control is required. If the DIU-DS is connected to a modem that
tracks carrier detect (AT&C1) SW1-4 should be On.
Содержание Strata AirLink DK40i
Страница 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Страница 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Страница 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Страница 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Страница 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Страница 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Страница 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Страница 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Страница 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...