Universal Slot PCBs
RDTU – T1 Interface Unit
9-54
Strata DK I&M 6/00
Notes
●
Function codes set in Program 76-1X-Y will override RSSU, PIOU2, and/or PIOUS2 function
codes (41, 42, 43) set in Program 03.
●
The TTY and modem function cannot operate on separate RSIU, RSIS, RMDS ports
simultaneously. If both functions are programmed at the same time on separate ports, the
function of the lowest numbered RSIU, RSIS, RMDS port (TTY or modem) will be active.
●
When uploading Program 76-1 with DKi Admin or DKi Backup, the data will not change until
the system power is cycled.
Program 76-2X-Z: Assigns each installed RSIU port to operate at a specified transmission rate.
Where X identifies the RSIU port no. 1~4 (see
for RSIU port number configuration)
and Z identifies the RSIU, RSIS, RMDS port transmission rate in bits-per-second (bps).
Notes
●
The sum of the used RSIU, RSIS, RMDS ports transmission rates cannot exceed 9600 bps.
Ports assigned as “non-function” (code 0) in Program 76-2X-Y will not be included in the
transmission rate sum. The RMDS will only function at 1200 or 2400 bps.
●
When uploading Program 76-2 with DKi Admin or DKi Backup make sure that Program 76-2
bps rate for the TTY/ modem port is set the same in: DKi Admin communications setup,
DKi Admin customer database, and any DK424 and DK424i RCTU. If the bps rate is not the
same in all three areas, uploading will fail on Program 76
Program 77-1, LED 14: Enables the RMDS modem function. If the RMDS should function as a
modem, turn On LED 14. If the RMDS should function as a RS-232 port, turn Off LED 14.
Program 77-1, LED 15: Sets the RMDS communications standard type to CCITT/V.22bis (2400
bps) or Bell 212A (1200 bps). The standard set in this program must match the standard of the
modem communicating with the DK424 and DK424i RMDS.
If the RMDS modem standard should be CCITT/V.22bis, turn LED 15 On. If the RMDS standard
should be Bell 212A, turn LED 15 Off. Most Hayes compatible modems will function with either
standard. Check with the modem manufacturer’s documentation to verify which protocol should
be used. When the system is initialized the Bell 212A standard is set (LED 15 Off).
Program 77-4, LED 01/LED 02: Enables CLID, ANI, and/or DNIS information for ACD calls to
be sent from the RSIU OA port.
➤
Turn LED 01 On if the OA port should send CLID and/or ANI information for ACD calls.
➤
Turn LED 02 On if the OA port should send DNIS information for ACD calls.
Program 77-4 allows LED 01 and LED 02 to be turned On simultaneously, allowing CLID, ANI,
and DNIS information to be sent from the OA port for ACD calls.
The system will initialize with LED 01 and 02 Off—no CLID, ANI, or DNIS information will be
sent from the OA port for ACD calls.
Содержание Strata AirLink DK40i
Страница 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Страница 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Страница 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Страница 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Страница 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Страница 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Страница 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Страница 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Страница 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...