DK424 Configuration
Worksheet 5 – System Power Factor Check
4-38
Strata DK I&M 6/00
Cabinet Power Factor, PCB/Telephone Device
Calculate the total PF of each cabinet (must be less than 65). See Worksheet 2,
for PCB
quantity and type, and
The Total Cabinet PF must not exceed the limits shown in Max. PF Allowed, at the bottom of this
chart.
Note
Cabinets 2~7: Last two slots are available on the DK424 (RCTUE/F).
Cabinets
1
2
3
4
5
6
7
PCB
Type
PF
PCB
Type
PF
PCB
Type
PF
PCB
Type
PF
PCB
Type
PF
PCB
Type
PF
PCB
Type
PF
Slot
s
1
2
3
4
5
6
7
8
Power Factor
Cabinet PF
(subtotal)
Telephone/
Device PF
Cabinet PF
(total)
Max. PF
Allowed
(all cabinets
combined)
65
130
195
260
325
390
455
Содержание Strata AirLink DK40i
Страница 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Страница 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Страница 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Страница 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Страница 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Страница 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Страница 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Страница 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Страница 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...