ISDN Interfaces
RPTU Interface Unit
16-6
Strata DK I&M 6/00
The CSU is transparent to data, clock, and framing. It acts as a repeater, not a controller, for
timing. The CSU also acts as a signal regenerator and must be able to perform loop-back tests and
maintenance to both the network and DK RPTU. The CSU is the same type as used for T1 circuits
although it performs the function as NT1 for PRI ISDN in the ISDN reference model as shown in
DK40i Slot Assignments
The RPTU is allowed in the slots shown in
Table 16-3
DK40i Slot Assignments
Note
Slots 16, 17, and 18 can be used for other PCBs.
DK424 Slot Assignments
Up to eight RPTU PCBs can be installed in a DK424 or DK424i system providing up to 188 PRI
lines (B-channels). If RPTU (PRI) and RDTU (T1) PCBs are installed in the same DK424 or
DK424i, the maximum combined PCBs cannot exceed the numbers provided in
. The
PCBs must be placed in designated slots in each of the DK424 or DK424i cabinets per
. The next highest slot adjacent to the RPTU slot must be vacant.
Program 03 defines which cabinet slots contain RPTU PCBs. The maximum number of cards and
lines is listed in
Table 16-4
DK280 or DK424 Base Cabinet with BA3/BB4, C3/D4 with MBJU or DK280 Base with RCTUE3/F4
RPTU Allowed in
Slot
Leave Slot
Vacant
15
(see Note)
17
18
Cabinet
RPTU
1
/Vacant Slots
2
No.
Type
1
DK280 or DK424
(base)
13
1
/14
2
15
1
/16
2
2
DK280
21
1
/22
2
23
1
/24
2
25
1
/26
2
DK424 21
1
/22
2
23
1
/24
2
25
1
/26
2
3
DK280
31
1
/32
2
DK424 31
1
/32
2
4
DK280
41
1
/42
2
DK424 41
1
/42
2
5
DK280
51
1
/52
2
DK424 51
1
/52
2
6
DK280
61
1
/62
2
DK424 61
1
/62
2
1. Allowed RPTU slots.
2. Slots must be vacant if using more than 16 channels.
Содержание Strata AirLink DK40i
Страница 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Страница 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Страница 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Страница 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Страница 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Страница 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Страница 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Страница 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Страница 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...