Flow-X─ Function Reference
Flow-X General functions - fxAPI_Table6_1952
fxAPI_Table6_1952
°API (60°F, 0 psig) --> CTL
This function calculates the volume correction factor for temperature from the API gravity value at 60°F
and the observed temperature according to API 1952 Table 6.
Compliance
ASTM-IP Petroleum Measurement Tables, American Edition, United States Units of
Measurement, 1952
Boundaries
Table 6 contains values for the following range:
Input value
Normal Range
EU
API Gravity at 60 °F
0 .. 100
°API
Observed temperature
0 .. 300
°F
Note that the table does not cover the full range, e.g. for an API gravity of 70 the table only specifies
values between 0 .. 150 °F
Function inputs and outputs
Function inputs
Remark
EU
SW tag
Range
Default
Name
Optional tag name, tag
description and tag group
API at 60 °F
API gravity at 60°F and the
equilibrium pressure
°API
-20..120
0
Observed
temperature
°F
-100..400
60
Function
outputs
Remark
EU
SW tag
Alarm
Fallbac
k
Status
0: Normal
1: Input argument out of range
2: Calculation error
-
STS
FIOOR
CALC
1
CTL
Volume correction factor for temperature.
-
CTL
1
Calculation
out of range
With respect to the standard the input
values are:
0: In Range
1: Out of Range
-
OOR
0
Calculations
The table values are the standard, so no calculations are involved. The function performs an
interpolation between the table values that correspond to the input values.
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...