![Spirit flow-x Скачать руководство пользователя страница 217](http://html1.mh-extra.com/html/spirit/flow-x/flow-x_function-reference_1348386217.webp)
Flow-X─ Function Reference
4-217
Flow-X General functions - fxISO5167_ISA1932Nozzle
pressure at the downstream tapping
(p
2
).
Temperature
Location
1: Upstream
Input 'Temperature' represents the
upstream temperature (t
1
).
2: Downstream
Input 'Temperature represents the
temperature at the downstream
tapping (t
2
).
3: Recovered
Input 'Temperature' represents the
downstream temperature at a
location Where the pressure has
fully recovered (t
3
).
Since temperature measurement is
usually downstream of the flow
device this is the most common
setting.
-
2
Temperature
Correction
This parameter specifies how the
temperature should be corrected from
downstream to upstream conditions (or
vice versa)
1: (1-
)/
Isentropic expansion using (1-
)/
as
the temperature referral exponent
2: Constant
Isentropic expansion using input
'Temperature Exponent' as the
temperature referral exponent [-].
Please note that this value must be <
0
3: Joule Thomson
Isenthalpic expansion using input
'Temperature Exponent' as the Joule
Thomson coefficient [°C/bar].
This method is prescribed by
ISO5167-1:2003.
3
Temperature
Exponent
Refer to input Temperature Correction
Unit depends on input Temperature
Correction value
-
-
°C/bar
0
Density Location
This parameter specifies if and how the
density should be corrected from
downstream to upstream conditions (or
vice versa).
1: Upstream
Input 'Density' represents the
density at the upstream pressure
tapping (
1
).
2: Downstream
Input 'Density' represents the
density at the downstream tapping
(
2
).
3: Recovered
Input 'Density' represents the
density downstream at a location
Where the pressure has fully
recovered (
3
).
-
1
Density Exponent.
This factor is used when density correction
is enabled. The formula 1/
will be used
-
0
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...