Flow-X─ Function Reference
4-221
Flow-X General functions - fxISO5167_LongRadiusNozzle
location Where the pressure has
fully recovered (
3
).
Density Exponent.
This factor is used when density
correction is enabled. The formula
1/
will be used when the input value
is set to 0, else the input value will be
used.
For more details refer to section
'Density correction'.
-
0
Fluid
The type of fluid being measured
1: Gas
2: Liquid
-
1
Year Of Edition
1: Edition 1991
2: Edition 1998
3: Edition 2003
Only used for calculation of pressure
loss, with options 1 and 2 giving the
same result
-
3
Function outputs
Remark
EU
Status
0: Normal (No error condition)
1: Input argument out of range
2: No convergence
-
Mass flow rate
The calculated mass flow rate
tonne/h
Beta ratio
Nozzle to pipe ratio at upstream temperature
Nozzle diameter
At the upstream temperature
Pipe diameter
At the upstream temperature
Upstream pressure
Pressure at upstream tapping (p
1
)
bar(a)
Pressure at
downstream tapping
Pressure at downstream tapping (p
2
)
bar(a)
Recovered
downstream pressure
Fully recovered downstream pressure (p
3
)
bar(a)
Upstream temperature
Temperature at upstream tapping (t
1
)
°C
Temperature at
downstream tapping
Temperature at downstream tapping (t
2
)
°C
Downstream
Temperature
'Fully recovered' downstream temperature (t
3
)
°C
Upstream density
Density at upstream tapping (
1
)
kg/m3
Density at downstream
tapping
Pressure at downstream tapping (
2
)
kg/m3
Downstream density
'Fully recovered' downstream density (
3
)
kg/m3
Reynolds number
The pipe Reynolds number (this is the Reynolds number
upstream of the Long Radius Nozzle and not the one within the
device throat itself
-
Discharge coefficient
-
Expansion Factor
-
Velocity of Approach
Pressure Range
0: Pressure is in valid range
1: Pressure is out of valid range
-
Reynolds Range
0: Reynolds number is in valid range
1: Reynolds number is out of valid range
-
Diameter Range
0: Device and pipe diameter and Beta ratio in valid range
1: Device diameter, pipe diameter and/or Beta ratio out of valid
range
-
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...