4-170
Flow-X─ Function Reference
Flow-X General functions - fxASTM_D1555_Dens60F
6.
The new value for density at [60
F, 0 psig] is calculated by dividing the observed
density by the CTL and CPL values.
7.
Steps 2 through 6 are repeated until the absolute difference between two
consecutive relative density values is less than the convergence limit of 1e-8.
When no convergence is achieved in 20 iterations then the status output is set to
‘No convergence’ and the density output is set to 0.