![Spirit flow-x Скачать руководство пользователя страница 154](http://html1.mh-extra.com/html/spirit/flow-x/flow-x_function-reference_1348386154.webp)
4-154
Flow-X─ Function Reference
Flow-X General functions - fxAPI_Table54_1980
fxAPI_Table54_1980
Density (15°C) --> CTL
This function calculates the volume correction factor for temperature CTL from the relative density
value at 15°C and the observed temperature.
The temperature conversion is according to API-2540, Tables 54A (Generalized Crude Oils) and 54B
(Refined Oil Products) and API MPMS 11.1 Chapter XIV Table 54D: 1984 (Lubricating Oils).
Compliance
API MPMS 11.1 Volume X (API Standard 2540) - Table 54A - Generalized Crude Oils,
Correction of Volume to 15°C against Density at 15°F - First Edition, August 1980
API MPMS 11.1 Volume X (API Standard 2540) - Table 54B - Generalized Products,
Correction of Volume to 15°C against Density at 15°C - First Edition, August 1980
API MPMS 11.1 Volume XIV - Table 54D - Generalized Lubricating Oils, Correction of Volume
to 15°C Against Density at 15°C - January 1982
Function
inputs
Remark
EU
SW tag
Range
Default
Name
Optional tag name, tag description
and tag group
Density at
15 °C
Density at 15°C and the equilibrium
pressure
kg/m3
0..1300
0
Observed
temperatur
e
°C
-100..200
15
Product
1: A - Crude Oil
2: B - Auto select
3: B - Gasoline
4: B - Transition Area
5: B - Jet Fuels
6: B - Fuel Oil
7: D - Lubricating Oil
PRDTYP
-
1
API2540
rounding
0: Disabled
The calculations are performed
with full precision and the final
CTL value is rounded as specified
by input 'CTL decimal places'
1: Enabled for computational value
API-2540 rounding and
truncating rules are applied and
the computational value for CTL
as specified in the standard is
used, meaning that the CTL value
has:
4 decimal places if CTL >=1
5 decimal places if CTL < 1.
2: Enabled for table value
API-2540 rounding and
truncating rules are applied and
the table value for CTL as
specified in the standard
meaning that the CTL value has 4
decimal places in all cases
3: Enabled with 5 decimal places
API-2540 rounding and
APIROUN
D
-
0
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...