4-116
Flow-X─ Function Reference
Flow-X General functions - fxAPI_RD60F_1980
8.
The compressibility factor is calculated according to API MPMS 11.2.1 from the
input density and temperature'. If API 11.2.1 rounding is enabled then the input
density and temperature are rounded and the calculations are performed in
accordance with the rounding and truncating rules of the standard.
9.
The CPL value is calculated from the compressibility factor and the 'Observed
pressure' and 'Equilibrium pressure' input values.
10.
The relative density at observed temperature and pressure is calculated from the
input relative density and the CTL and the CPL values.