Flow-X─ Function Reference
4-137
Flow-X General functions - fxAPI_Table23_1980
standard.
Hydrometer
correction
0: Disabled
1: Enabled
HYDROCO
R
0
Function
outputs
Remark
EU
SW tag
Alarm
Fallbac
k
Status
0: Normal
1: Input argument out of range
2: Calculation error
3: No convergence
-
STS
FIOOR
CALC
NOCONV
Relative
density 60 °F
Relative density at 60°F and the
equilibrium pressure
-
RD
0
CTL
Volume correction factor for
temperature.
-
CTL
1
K0
Actual value of constant K0 used for CTL
calculation
-
K0
0
K1
Actual value of constant K1 used for CTL
calculation
-
K1
0
K2
Actual value of constant K2 used for CTL
calculation
-
K2
0
Alpha
Thermal expansion factor
1/°F
ALPHA
0
Product
When input 'Product' is 'B - Auto select',
then the output is set to the actual
selected product of table 23B
(enumerative value as defined for input
'Product'), else the output is set equal to
input 'Product'.
-
PRDCU
R
0
Calculation
out of range
With respect to the standard the input
values are:
0: In Range
1: Out of Range
-
OOR
0
Calculations
The calculations are in full or partial compliance with the standard depending on input ‘API 2540
rounding’.
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...