4-192
Flow-X─ Function Reference
Flow-X General functions - fxGERG2008_Flash
Function
outputs
Remark
EU
SW tag
Alarm
Fallback
Status
0: Normal
1: Input argument out of range
2: Calculation error
3: No convergence
4: Mole fractions do not add up to
1.0 +- 0.0001
6: Hardware not supported
STS
FIOOR
CALCERR
NOCONV
COMPERR
Vapor fraction
FV
0
Compressibility
vapor
Compressibility of the vapor
fraction of the mixture
ZV
0
Compressibility
liquid
Compressibility of the liquid
fraction of the mixture
ZL
0
Compressibility
total
Compressibility of the mixture
Z
0
Density vapor
Density of the vapor fraction of
the mixture
kg/m3
DV
0
Density liquid
Density of the liquid fraction of
the mixture
kg/m3
DL
0
Density total
Density of the mixture
kg/m3
D
0
Calculations
The calculations are as documented in the standard.