4-82
Flow-X─ Function Reference
Flow-X General functions - fxAPI_Dens15C_NGL_LPG
values are not rounded
1: Enabled
The related values are
rounded as defined in the
standard
Equilibrium
pressure
mode
1: Use Input
The value of input
'Equilibrium pressure value'
is used for the calculation of
CPL
2: GPA TP-15
The equilibrium pressure is
calculated in accordance
with GPA TP-15
EQUIPMODE
2
Equilibrium
pressure
value
Only used when input
'Equilibrium pressure mode' is
set to 'Use input'.
The value will be used for the
calculation of the CPL
bar(a)
EQUIPINP
0
GPA TP-15
rounding
Only used when 'Equilibrium
pressure mode is set to 'GPA TP-
15'
0: Disabled
Full precision (no rounding
and truncating applied)
1: Enabled
Rounding as defined in '
GPA TP15:1988 / API MPMS
11.2.2 Addendum':1994
-
TP15RND
0
P100
Correlation
Only used when 'Equilibrium
pressure mode is set to 'GPA TP-
15'
0: Disabled
The standard correlation is
commonly used for pure
products such as propane,
butane and natural gasoline.
It only requires the relative
density and the temperature
to calculate the vapor
pressure
1: Enabled
The improved correlation
requires the vapor pressure
at 100°F (37.8 °C). This
method is better suited for
varied NGL mixes Where
different product mixes
could have the same specific
gravity but different
equilibrium pressures.
-
P100CORR
0
Vapor
pressure at
100°F
Only used when 'Equilibrium
pressure mode is set to 'GPA TP-
15' and the P100 correlation is
enabled.
bar(a)
EQUIP100F
0..200
0
Conversion
method
1: From observed to standard
conditions
2: From standard to observed
conditions
CONVMETH
1
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...