![Spirit flow-x Скачать руководство пользователя страница 313](http://html1.mh-extra.com/html/spirit/flow-x/flow-x_function-reference_1348386313.webp)
Flow-X─ Function Reference
4-313
Flow-X General functions - fxVCone_M
2: Downstream
Input 'Density' represents the
density at the downstream tapping
(
2
).
3: Recovered
Input 'Density' represents the
density downstream at a location
Where the pressure has fully
recovered (
3
).
Density Exponent.
This factor is used when density
correction is enabled. The formula 1/
will be used when the input value is set
to 0, else the input value will be used.
For more details refer to section 'Density
correction'.
-
0
Fluid
The type of fluid being measured
1: Gas
2: Liquid
-
1
Discharge coefficient
The discharge coefficient of the meter as
specified by the manufacturer.
The McCrometer reference document
states that the discharge coefficient is a
function of Reynolds number. It is
advised that the meter is calibrated
across the range of Reynold numbers for
which the meter is used.
The resulting correction curve can be
implemented through function
fxInterolationCurve. Input 'Discharge
coefficient' needs to be linked to the
corresponding output of this additional
function.
-
0..2
0.85
Function outputs
Remark
EU
Fallback
Status
0: Normal (No error condition)
1: Input argument out of range
2: No convergence
Mass flow rate
The calculated mass flow rate
tonne/h
0
Beta ratio
Cone to pipe diameter ratio at upstream
temperature
-
Input Cone
diameter /
Input Pipe
diameter
Cone diameter
At the upstream temperature
mm
Input Cone
diameter
Pipe diameter
At the upstream temperature
mm
Input Pipe
diameter
Upstream pressure
Pressure at upstream tapping (p
1
)
bar(a)
Input
Pressure
Pressure at
downstream
tapping
Pressure at downstream tapping (p
2
)
bar(a)
Input
Pressure
Recovered
downstream
pressure
Fully recovered downstream pressure (p
3
)
bar(a)
Input
Pressure
Upstream
temperature
Temperature at upstream tapping (t
1
)
°C
Input
Temperature
Temperature at
downstream
Temperature at downstream tapping (t
2
)
°C
Input
Temperature
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...