Flow-X─ Function Reference
4-125
Flow-X General functions - fxAPI_Table5_1952
fxAPI_Table5_1952
°API (T) --> °API (60°F)
This function converts an API gravity value at the observed temperature to the API gravity value at 60°F
in accordance with API 1952 Table 5.
Compliance
ASTM-IP Petroleum Measurement Tables, American Edition, United States Units of
Measurement, 1952
Function inputs
Remark
EU
SW
tag
Range
Defaul
t
Name
Optional tag name, tag description
and tag group
Observed API
Observed API gravity
°API
-20..120
0
Observed
temperature
Temperature at which the API gravity
is observed
°F
-100..400
60
Function
outputs
Remark
EU
SW tag
Alarm
Fallback
Status
0: Normal
1: Input argument out of range
2: Calculation error
3: No convergence
-
STS
FIOOR
CALCERR
NOCONV
1
API at 60 °F
API gravity at 60°F
°API
API
0
Calculation out
of range
With respect to the standard the
input values are:
0: In Range
1: Out of Range
-
OOR
0
Calculations
The table values are the standard, so no calculations are involved. The function performs an
interpolation between the table values that correspond to the input values.
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...