![Spirit flow-x Скачать руководство пользователя страница 155](http://html1.mh-extra.com/html/spirit/flow-x/flow-x_function-reference_1348386155.webp)
Flow-X─ Function Reference
4-155
Flow-X General functions - fxAPI_Table54_1980
truncating rules are applied,
while the CTL value has 5
decimal places in all cases.
Note: although not strictly in
accordance with the standard,
this option is more commonly
used than option 'Enabled for
computational value'
Function outputs
Remark
EU
SW tag
Alarm
Fallback
Status
0: Normal
1: Input argument out of
range
2: Calculation error
STS
FIOOR
CALCERR
CTL
Volume correction factor
for temperature.
Value will be rounded
according to input 'API2540
rounding'
-
CTL
1
K0
Actual value of constant K0
used for CTL calculation
-
K0
0
K1
Actual value of constant K1
used for CTL calculation
-
K1
0
K2
Actual value of constant K2
used for CTL calculation
-
K2
0
Alpha
Thermal expansion factor
1/°C
ALPHA
Product
When input 'Product' is 'B -
Auto select', then the
output is set to the actual
selected product of table
54B (enumerative value as
defined for input 'Product'),
else the output is set equal
to input 'Product'.
-
PRDCUR
Calculation out of
range
With respect to the
standard the input values
are:
0: In Range
1: Out of Range
-
OOR
Calculations
The calculations are in full or partial compliance with the standard depending on input ‘API 2540
rounding’.
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...