![Spirit flow-x Скачать руководство пользователя страница 301](http://html1.mh-extra.com/html/spirit/flow-x/flow-x_function-reference_1348386301.webp)
Flow-X─ Function Reference
4-301
Flow-X General functions - fxTotalizerRate
Reset flag
Flag indicating a reset to 0.
0: Off
1: On
Note: stays 'On' for one cycle only
RESET
Reload
warning
Flag that indicates that at startup
only 2 of the 3 copies were equal
and that that value is used as the
initial total.
0: Off
1: On
Note: stays 'On' for one cycle only
RLWARN
Reload error
Flag that indicates that at startup
all 3 copies were different and the
total was reset to 0
0: Off
1: On
Note: stays 'On' for one cycle only
RLERR
Unit conversion
The function will automatically apply the required conversion based on the unit of the flow rate input
value (Input unit) and the selected 'Output unit' for the flow quantity.
E.g. when flow rate input is in 'kg/hr' the selected unit is 'tonne' then the following conversions are
applied:
3.
The flow rate value is converted to the corresponding base unit, which is 'kg/s' for a 'Mass
per Time' unit
4.
The flow increment over the last calculation cycle is calculated from the 'kg/s' value and the
actual calculation cycle time, resulting in a value expressed in 'kg' (i.e. the base unit for
'Mass').
5.
The flow increment is converted from 'kg' to 'tonne' before the cumulative total and
increment output values are updated.
Similar conversions are applied for flow rates that are expressed in volume, standard volume, normal
volume and energy units.
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...