![Spirit flow-x Скачать руководство пользователя страница 278](http://html1.mh-extra.com/html/spirit/flow-x/flow-x_function-reference_1348386278.webp)
4-278
Flow-X─ Function Reference
Flow-X General functions - fxSGERG_C
pressure
1: 60°F / 60 °F / 14.73 psia
2: 60 °F / 60 °F / 1.01592 bar
Note: the calculations are based on 25°C /
0°C / 1.01325 bar(a). For the other
conditions conversion factors are applied
as specified in GERG Technical Monograph
5, Standard GERG Virial Equation, 1991.
Refer to section 'Calculations' for more
details
Function
outputs
Remark
EU
SW tag
Alarm
Fallback
Status
0: Normal
1: Input argument out of range
2: Calculation error
3: No convergence
STS
FIOOR
CALCERR
NOCONV
Compressibility
factor
-
1
Molar mass
lb/lbmol
0
Range
0: In Normal Range
All components are
within the 'Normal
Range'
1: In Extended Range
One or more
components within the
'Extended Range, but
none of the components
outside the Extended
rang (outputs values
have higher uncertainty)
2: Out of Range
One or more
components outside the
'Extended Range' (using
the AGA8 calculation is
not recommended in
this case)
RANGE
OOR
0
Calculations
The calculations are in accordance with the standard.
As specified in the standard and depending on the selected reference conditions (input 'Reference
conditions') one of the following set of conversions is carried out to obtain the input values of the
relative density (RD) at 0°C and 1.01325 bar(a) and the gross heating value (GHV) at 25°C and 1.01325
bar(a) combustion and 0°C and 1.01325 bar(a) metering conditions.
Input 'Reference Conditions'
Multiply input GHV with
Multiply input RD with
60 °F, 60 °F @ 14.73 psia
1.0543/26.85
1.0002
60 °F, 60 °F @ 1.01592 bar(a)
1.0543/26.86
1.0002
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...