![Spirit flow-x Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/spirit/flow-x/flow-x_function-reference_1348386076.webp)
4-76
Flow-X─ Function Reference
Flow-X General functions - fxAPI_Dens15C_1980
Function
inputs
Remark
EU
SW tag
Range
Default
Name
Optional tag name, tag
description and tag group
Input density
Meaning depends on the input
'Conversion method'.
'Conversion method' = 1
Density at the observed
temperature and pressure
'Conversion method' = 2
Density at 15 °C and the
equilibrium pressure.
kg/m3
0..1300
0
Observed
temperature
°C
-100..200
15
Observed
pressure
bar(g)
-1..150
0
Product
1: A - Crude Oil
2: B - Auto select
Selection based on density at 15
°C
3: B - Gasoline
4: B - Transition Area
5: B - Jet Fuels
6: B - Fuel Oil
7: D - Lubricating Oil
PRDTYP
1
API 2540
rounding
0: Disabled
The calculations are
performed with full
precision and the final CTL
value is rounded as
specified by input 'CTL
decimal places'
1: Enabled for computational
value
API-2540 rounding and
truncating rules are applied
and, in case of conversion
method 2 (standard to
observed), the
computational value for CTL
as specified in Table 54 is
used, meaning that the CTL
value has:
4 decimal places if CTL >=1
5 decimal places if CTL < 1.
2: Enabled for table value
API-2540 rounding and
truncating rules are applied
and, in case of conversion
method 2 (standard to
observed), the table value
for CTL as specified in Table
54 meaning that the CTL
value has 4 decimal places
in all cases
3: Enabled with 5 decimal places
API-2540 rounding and
truncating rules are applied,
API2540RND
-
0
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...