Flow-X─ Function Reference
Flow-X General functions - fxVCone_M
tapping
Downstream
Temperature
'Fully recovered' downstream temperature (t
3
)
°C
Input
Temperature
Upstream density
Density at upstream tapping (
1
)
kg/m3
Input Density
Density at
downstream
tapping
Pressure at downstream tapping (
2
)
kg/m3
Input Density
Downstream
density
'Fully recovered' downstream density (
3
)
kg/m3
Input Density
Reynolds number
-
0
Discharge
coefficient
Same as input value
-
Expansion Factor
-
0
Velocity
Pipeline velocity
m/s
0
Expansion Factor
Range
The McCrometer reference document states that
for gas applications the expansion factor should
not get below 0.84
0: Expansion factor is in valid range
1: Expansion factor is out of valid range
-
0
Calculations
The flow calculation is as specified in the McCrometer reference document.
The downstream to upstream correction (and vice versa) for pressure, temperature and density are as
specified for function 'ISO 5167 Orifice'.