4-132
Flow-X─ Function Reference
Flow-X General functions - fxAPI_Table6_1980
cases
3: Enabled with 5 decimal places
API-2540 rounding and
truncating rules are applied,
while the CTL value has 5
decimal places in all cases.
Note: although not strictly in
accordance with the
standard, this option is more
commonly used than option
'Enabled for computational
value'
Function
outputs
Remark
EU
SW tag
Alarm
Fallback
Status
0: Normal
1: Input argument out of range
2: Calculation error
-
STS
FIOOR
CALC
1
CTL
Volume correction factor for
temperature.
Value will be rounded according to
input 'API2540 rounding'
-
CTL
1
K0
Actual value of constant K0 used for
CTL calculation
-
K0
0
K1
Actual value of constant K1 used for
CTL calculation
-
K1
0
K2
Actual value of constant K2 used for
CTL calculation
-
K2
0
Alpha
Thermal expansion factor
1/°F
ALPHA
0
Product
When input 'Product' is 'B - Auto
select', then the output is set to the
actual selected product of table 6B
(enumerative value as defined for
input 'Product'), else the output is set
equal to input 'Product'.
-
PRDCUR
0
Calculation
out of range
With respect to the standard the
input values are:
0: In Range
1: Out of Range
-
OOR
0
Calculations
The calculations are in full or partial compliance with the standard depending on input ‘API 2540
rounding’.
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...